GROUT INJECTION PUMP |
GROUT INJECTION PUMP
Jet grouting is achieved in two versions: compact and standard.
The former is made up of two hydraulic cylinders and of a central injector; in addition, it has the same technical characteristics as the standard model.
The latter is typified by a hydraulic cylinder placed on top of the central injector, which is formed by two ball valves and a tie rod system.
The technical characteristics are specified below. |
|
|
Oil
|
PC100/1C/80
|
PC200/1C/80
|
PC200/2C/80
|
PC200/2C-2I/80
|
|
|
|
STANDARD |
COMPACT |
|
FAST FILLING |
Oil flowrate |
30 l/min. |
60 l/min. |
60 l/min. |
120l/min. |
|
Cement side pressure |
30-35 bar |
30-35 bar |
30-35 bar |
30-35 bar |
|
Thrust for minute |
30 max |
60 max |
60 max |
60 max |
|
Oil maximum pressure |
60-70 bar |
60-70 bar |
60-70 bar |
60-70 bar |
|
Oil capacity jacks |
0,436 dm³ |
0,872 dm³ |
0,872 dm³ |
1,69 dm³ |
|
Electric engine power |
2,2 kW - 3 Cv |
7,35 kW - 10 Cv |
7,35 kW - 10 Cv |
9 kW - 12 Cv |
|
SLOW FILLING |
Oil Flowrate |
4,5 l/min. |
10 l/min. |
10 l/min. |
12 l/min. |
|
Cement side pressure |
80-85 bar |
80-85 bar |
80-85 bar |
80-85 bar |
|
Thrust for minute |
10 |
10 |
10 |
6 |
|
Oil maximum pressure |
200-210 bar |
200-210 bar |
200-210 bar |
190 bar |
|
Electric engine power |
2,2 kW - 3 Cv |
7,35 kW - 10 Cv |
7,35 kW - 10 Cv |
9 kW - 12 Cv |
| FOR DIFFERENT PRESSURES AND FLOWRATES YOU CAN CONSULT OUR ENGINEERING DEPARTMENT |

|
Zoom |
|